/[pcre]/code/trunk/doc/pcreapi.3
ViewVC logotype

Diff of /code/trunk/doc/pcreapi.3

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 1369 by ph10, Sat Oct 5 15:45:11 2013 UTC revision 1370 by ph10, Wed Oct 9 10:18:26 2013 UTC
# Line 1  Line 1 
1  .TH PCREAPI 3 "05 October 2013" "PCRE 8.34"  .TH PCREAPI 3 "08 October 2013" "PCRE 8.34"
2  .SH NAME  .SH NAME
3  PCRE - Perl-compatible regular expressions  PCRE - Perl-compatible regular expressions
4  .sp  .sp
# Line 919  have fallen out of use. To avoid confusi Line 919  have fallen out of use. To avoid confusi
919    31  POSIX collating elements are not supported    31  POSIX collating elements are not supported
920    32  this version of PCRE is compiled without UTF support    32  this version of PCRE is compiled without UTF support
921    33  [this code is not in use]    33  [this code is not in use]
922    34  character value in \ex{...} sequence is too large    34  character value in \ex{} or \eo{} is too large
923    35  invalid condition (?(0)    35  invalid condition (?(0)
924    36  \eC not allowed in lookbehind assertion    36  \eC not allowed in lookbehind assertion
925    37  PCRE does not support \eL, \el, \eN{name}, \eU, or \eu    37  PCRE does not support \eL, \el, \eN{name}, \eU, or \eu
# Line 967  have fallen out of use. To avoid confusi Line 967  have fallen out of use. To avoid confusi
967    75  name is too long in (*MARK), (*PRUNE), (*SKIP), or (*THEN)    75  name is too long in (*MARK), (*PRUNE), (*SKIP), or (*THEN)
968    76  character value in \eu.... sequence is too large    76  character value in \eu.... sequence is too large
969    77  invalid UTF-32 string (specifically UTF-32)    77  invalid UTF-32 string (specifically UTF-32)
970      78  setting UTF is disabled by the application
971      79  non-hex character in \ex{} (closing brace missing?)
972      80  non-octal character in \eo{} (closing brace missing?)
973      81  missing opening brace after \eo
974  .sp  .sp
975  The numbers 32 and 10000 in errors 48 and 49 are defaults; different values may  The numbers 32 and 10000 in errors 48 and 49 are defaults; different values may
976  be used if the limits were changed when PCRE was built.  be used if the limits were changed when PCRE was built.
# Line 2866  Cambridge CB2 3QH, England. Line 2870  Cambridge CB2 3QH, England.
2870  .rs  .rs
2871  .sp  .sp
2872  .nf  .nf
2873  Last updated: 05 October 2013  Last updated: 08 October 2013
2874  Copyright (c) 1997-2013 University of Cambridge.  Copyright (c) 1997-2013 University of Cambridge.
2875  .fi  .fi

Legend:
Removed from v.1369  
changed lines
  Added in v.1370

  ViewVC Help
Powered by ViewVC 1.1.5